Wallplate installation

Remove the wallplate from the thermostat by pulling from the bottom, then follow directions below for mounting.
Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (2)

  1. Pull wires through wire hole.
    Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (3)
  2. Position wallplate on wall, level and mark hole positions with pencil.
  3. Drill holes at marked positions as shown below, then tap in supplied wall anchors.
  4. Place wallplate over anchors, insert and tighten mounting screws.

Read before installing

Power options

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (4)
Keep wires in this shaded area
Remove factory installed jumper only for two-transformer systems.
Insert batteries for primary or backup power
Connect C for primary AC power (optional if batteries are installed).

Wiring terminal designations

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (5)
TH3110D

C 24 Vac common. For 2 transformer systems, use common wire from cooling transformer.
B Changeover valve energized in heating
R 24 Vac power from heating transformer
Rc 24 Vac power from cooling transformer
O Changeover valve energized in cooling
G Fan relay
Y Compressor contactor
W Heat relay

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (6)
TH3210D

C 24 Vac common
B Changeover valve energized in heating R 24 Vac power
L Sends output when set to Em. Heat
O Changeover valve energized in cooling
G Fan relay
Y Compressor contactor
Aux Auxiliary heat relay
E Emergency heat relay

Wiring conventional and heat pump systems

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (7)
2H/1C Heat Pump System TH3210D

C 24 Vac common [3]
B Changeover valve energized in heating [5]
R Power [1]
L Sends output when set to Em. Heat [8]
O Changeover valve energized in cooling [5]
G Fan relay
Y Compressor contactor
Aux Auxiliary heat relay [9]
E Emergency heat relay [9]

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (8)
1H/1C System TH3110D (1 transformer)

C 24 Vac common [3]
R [R+Rc joined by jumper]
Rc Power [1]
G Fan relay
Y Compressor contactor
W Heat relay

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (9)
1H/1C System TH3110D (2 transformers)

C 24 Vac common [3, 4]
R Power (heating transformer) [1, 2]
Rc Power (cooling transformer) [1, 2]
G Fan relay
Y Compressor contactor
W Heat relay

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (10)
1H/1C Heat Pump System TH3110D [7]

C 24 Vac common [3]
B Changeover valve energized in heating [5]
R [R+Rc joined by jumper]
Rc Power [1]
O Changeover valve energized in cooling [5]
G Fan relay
Y Compressor contactor [6]
W [W+Y joined by jumper]

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (11)
Heat Only System TH3110D

C 24 Vac common [3]
R [R+Rc joined by jumper]
Rc Power [1]
W Heat relay

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (12)
Heat Only System with Fan TH3110D

C 24 Vac common [3]
R [R+Rc joined by jumper]
Rc Power [1]
G Fan relay
W Heat relay

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (13)
Cool Only System TH3110D

C 24 Vac common [3]
R [R+Rc joined by jumper]
Rc Power [1]
G Fan relay

NOTES

Wire specifications:
Use 18- to 22-gauge thermostat wire. Shielded cable is not required.

  1. Power supply. Provide disconnect means and overload protection as required.
  2. Remove jumper for 2-transformer systems.
  3. Optional 24 Vac common connection.
  4. Common connection must come from cooling transformer.
  5. Use either O or B terminals for changeover valve.
  6. Use a small piece of wire (not supplied) to connect W and Y terminals.
  7. Set fan operation switch to Heat Pump and configure system type for heat pump.
  8. L terminal sends a continuous output when thermostat is set to Em. Heat. Connect to Honeywell Home zoning panels to switch the panel to Emergency Heat.
  9. Install field jumper between Aux and E if there is no emergency heat relay.

Fan operation settings (TH3110D only)

Gas or Oil: For gas or oil heating systems, leave the fan operation switch in this factory-set position. (This setting is for systems that control the fan in a call for heat.) Electric or Heat Pump: Change the switch to this setting for heat pump or electric heat systems. (This setting is for systems that allow the thermostat to control the fan in a call for heat, if a fan wire is connected to the G terminal.)
Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (14)

Thermostat mounting

  1. Align the 4 tabs on the wallplate with corresponding slots on the back of the thermostat.
    Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (15)
  2. Push gently until the thermostat snaps in place.
  3. Push excess wire back into the wall opening.
  4. Plug wall opening with nonflammable insulation.

Installer Setup

Follow the procedure below to configure the thermostat to match the installed heating/cooling system, and customize feature operation as desired.
Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (16)

To begin, press and hold the Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (17) and Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (18) buttons until the display changes.

  • Press Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (19) to change settings.
  • Press Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (20) to advance to next function.
  • Press and hold Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (21)Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (22) to exit and save settings.

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (23)

Setup function Settings & options (factory settings in bold)
1 System type TH3110D only

1

Gas, oil or electric heat with air conditioning

Heat pump (5 minute compressor off time in heating and cooling)

5 Heating cycle rate
(CPH: cycles/hour)
TH3110D only

5

1

3

9

For gas or oil furnaces of less than 90% efficiency For steam or gravity systems

For hot water systems & furnaces of over 90% efficiency

For electric furnaces

[Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]

6 Auxiliary heat cycle rate
(CPH) TH3210D only

5

1

3

9

For gas or oil furnaces of less than 90% efficiency For steam or gravity systems

For hot water systems & furnaces of over 90% efficiency

For electric furnaces

[Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]

8 Emergency heat cycle rate
(CPH) TH3210D only

9

1

3

5

For electric emergency heat

For steam or gravity systems

For hot water systems & furnaces of over 90% efficiency For gas or oil furnaces of less than 90% efficiency

[Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]

9 Compressor cycle rate (CPH) 3 Recommended for most compressors
[Other cycle rate options: 1, 2, 4, 5, or 6 CPH]
14 Temperature display

1

Fahrenheit

Celsius

15 Compressor protection 5 Five-minute compressor off time
[Other options: 0, 1, 2, 3 or 4-minute off time]

Compressor Protection (Setup Function 15): Forces the compressor to wait a few minutes before restarting, to prevent damage. During the wait time, the message Cool On or Heat On (heat pumps only) will flash on the display.

Installer system test

  1. Set SYSTEM switch to Heat.
    Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (24)
  2. Press t to turn on and check systems (see table, below).
  3. Press t until systems turn off.
  4. Set SYSTEM switch to Em Heat and repeat steps 2-3 above (TH3210D only).
  5. Set SYSTEM switch to Cool and repeat steps 2-3 above.
  6. Press and hold ts to terminate test at any time.

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (25)

System test System status
10 Heating system 0 Heat and fan turn off.
1 Heat turns on.
2 Auxiliary heat turns on (TH3210D only).
20 Emergency heat

1

2

Heat and fan turn on. (TH3210D only)

Heat and fan turn off.(TH3210D only)

Auxiliary heat turns on. (TH3210D only)

30 Cooling system

2

Compressor and fan turn off.

Compressor and fan turn on.

70 Thermostat information
(for reference only)

71

72

73

74

75

76

Software revision number (major revisions)

Software revision number (minor revisions)

Configuration identification code (major)

Configuration identification code (minor)

Production configuration date code (week)

Production configuration date code (year)

Troubleshooting

If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily.

Display is blank
  • Check circuit breaker and reset if necessary.
  • Make sure power switch at heating & cooling system is on.
  • Make sure furnace door is closed securely.
  • Make sure fresh AA alkaline batteries are correctly installed.
Heating or cooling system does not respond
  • Set system switch to Heat. Make sure the temperature is set higher than the Inside temperature.
  • Set system switch to Cool. Make sure the temperature is set lower than the Inside temperature.
  • Wait 5 minutes for the system to respond.
Temperature settings do not change Make sure heating and cooling temperatures are set to acceptable ranges:
  • Heat: 40° to 90°F (4.5° to 32°C).
  • Cool: 50° to 99°F (10° to 37°C).
"Cool On" or "Heat On" is flashing
  • Compressor protection feature is engaged. Wait 5 minutes for the system to restart safely, without damage to the compressor.
"Heat On" is not displayed
  • Set the System switch to Heat, and set the temperature level above the current room temperature.
"Cool On" is not displayed
  • Set the System switch to Cool, and set the temperature level below the current room temperature.

Specifications

Temperature Ranges
Heat: 40° to 90°F (4.5° to 32°C)

Cool: 50° to 99°F (10° to 37°C)

Operating Ambient Temperature
32° to 120°F (0° to 48.9°C)

Shipping Temperature
-20° to 120°F (-28.9° to 48.9°C)

Operating Relative Humidity
5% to 90% (non-condensing)

Physical Dimensions
3-13/16" H x 5-3/8" W x 1-1/4" D

97 mm H x 137 mm W x 32 mm D

Input: 24 V~ @ 60 Hz, 1.0 A

Electrical Ratings
Heat (1st stage) 20-30 Vac 0.02-1.0 A
(Powerpile) 750 mV DC 100 mA DC
Emergency heat 20-30 Vac 0.02-1.0 A
Auxiliary heat 20-30 Vac 0.02-1.0 A
Cooling 20-30 Vac 0.02-1.0 A

Need Help?

For assistance with this product, please visit customer.resideo.com.
Or call Customer Care toll-free at 1-800-468-1502.

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (26)

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (27)
EQUIPMENT DAMAGE HAZARD
Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (28)
ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before beginning installation.

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (29)
MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal.

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (30)
ELECTRONIC WASTE NOTICE
The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The correct disposal of end-of-life equipment will help prevent potential negative consequences for the environment and human health.

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (31)

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual

Honeywell TH3110D1008, TH3210D1004, PRO 3000 Series - Non-Programmable Digital Thermostat Manual (2024)
Top Articles
Latest Posts
Article information

Author: Virgilio Hermann JD

Last Updated:

Views: 6482

Rating: 4 / 5 (41 voted)

Reviews: 88% of readers found this page helpful

Author information

Name: Virgilio Hermann JD

Birthday: 1997-12-21

Address: 6946 Schoen Cove, Sipesshire, MO 55944

Phone: +3763365785260

Job: Accounting Engineer

Hobby: Web surfing, Rafting, Dowsing, Stand-up comedy, Ghost hunting, Swimming, Amateur radio

Introduction: My name is Virgilio Hermann JD, I am a fine, gifted, beautiful, encouraging, kind, talented, zealous person who loves writing and wants to share my knowledge and understanding with you.